← Oklahoma

Tap water quality report

Wagoner, OK

EPA monitoring detected 21 contaminants across the 5 water suppliers serving Wagoner. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

5
water suppliers
16,242
people served
21
contaminants found

What was found in Wagoner's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Copper
495.1 µg/L 38%
of the EPA limit 1300 µg/L
Main supplier: WAGONER · 7,982 people · 2018
Highest in the city: 1060.899999999999 µg/L — WAGONER CO. RWD #6 · 1,500 people · 2019
5/5 SYR4
Nitrate-Nitrite
920 µg/L 9.2%
of the EPA limit 10000 µg/L
Main supplier: WAGONER · 7,982 people · 2019
4/5 SYR4
TTHM
89.33000000000001 µg/L 112%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
Main supplier: WAGONER · 7,982 people · 2019
Highest in the city: 103.75 µg/L — WAGONER CO. RWD #6 · 1,500 people · 2019
5/5 SYR4
Fluoride
100 µg/L 2.5%
of the EPA limit 4000 µg/L
Highest in the city: WAGONER CO. RWD #1 · 397 people · 2013
1/5 SYR4
Chloroform
68.49 µg/L
No EPA limit set
Main supplier: WAGONER · 7,982 people · 2019
Highest in the city: 76.6 µg/L — WAGONER CO. RWD #9 · 4,363 people · 2019
5/5 SYR4
Total Haloacetic Acids (HAA5)
67.295 µg/L 112%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
Main supplier: WAGONER · 7,982 people · 2019
Highest in the city: 74.3385 µg/L — WAGONER CO. RWD #9 · 4,363 people · 2019
5/5 SYR4
Barium
40.2 µg/L 2%
of the EPA limit 2000 µg/L
Main supplier: WAGONER · 7,982 people · 2013
Highest in the city: 58 µg/L — WAGONER CO. RWD #2 · 2,000 people · 2013
4/5 SYR4
Monochloroacetic Acid
5.177999999999999 µg/L
No EPA limit set
Main supplier: WAGONER · 7,982 people · 2019
Highest in the city: 53.66499999999992 µg/L — WAGONER CO. RWD #2 · 2,000 people · 2019
5/5 SYR4
Chlorite
50.129999999999995 µg/L 5%
of the EPA limit 1000 µg/L
Main supplier: WAGONER · 7,982 people · 2015
1/5 SYR4
Dichloroacetic Acid
30.354999999999997 µg/L
No EPA limit set
Main supplier: WAGONER · 7,982 people · 2019
Highest in the city: 40.169999999999995 µg/L — WAGONER CO. RWD #9 · 4,363 people · 2019
5/5 SYR4
Trichloroacetic Acid
31.544999999999998 µg/L
No EPA limit set
Main supplier: WAGONER · 7,982 people · 2019
Highest in the city: 37.96 µg/L — WAGONER CO. RWD #6 · 1,500 people · 2019
5/5 SYR4
Bromodichloromethane
18.779999999999998 µg/L
No EPA limit set
Main supplier: WAGONER · 7,982 people · 2019
Highest in the city: 20.155 µg/L — WAGONER CO. RWD #6 · 1,500 people · 2019
5/5 SYR4
Lead
5.2 µg/L 35%
of the EPA limit 15 µg/L
Main supplier: WAGONER · 7,982 people · 2018
Highest in the city: 19 µg/L — WAGONER CO. RWD #9 · 4,363 people · 2018
3/5 SYR4
Dibromochloromethane
6.2604999999999995 µg/L
No EPA limit set
Main supplier: WAGONER · 7,982 people · 2019
5/5 SYR4
Gross Beta Particle Activity
6.06 pCi/L
No EPA limit set
Main supplier: WAGONER · 7,982 people · 2016
4/5 SYR4
Monobromoacetic Acid
1.3 µg/L
No EPA limit set
Main supplier: WAGONER · 7,982 people · 2019
Highest in the city: 1.9425 µg/L — WAGONER CO. RWD #9 · 4,363 people · 2019
4/5 SYR4
Dibromoacetic Acid
1.8325 µg/L
No EPA limit set
Main supplier: WAGONER · 7,982 people · 2019
5/5 SYR4
Dalapon
1.12 µg/L 0.6%
of the EPA limit 200 µg/L
Highest in the city: WAGONER CO. RWD #2 · 2,000 people · 2018
1/5 SYR4
Gross Alpha, Excl. Radon And U
1.11 pCi/L 7.4%
of the EPA limit 15 pCi/L
Highest in the city: WAGONER CO. RWD #9 · 4,363 people · 2019
1/5 SYR4
Combined Radium (-226 And -228)
0.7030 pCi/L 14%
of the EPA limit 5 pCi/L
Highest in the city: WAGONER CO. RWD #9 · 4,363 people · 2019
2/5 SYR4
Lead
0.0027 mg/L 18%
of the EPA limit 0.0150 mg/L
Main supplier: WAGONER · 7,982 people · 2026
Highest in the city: 0.0080 mg/L — WAGONER CO. RWD #9 · 4,363 people · 2026
5/5 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Wagoner

SupplierPopulation served
WAGONER 7,982
WAGONER CO. RWD #9 4,363
WAGONER CO. RWD #2 2,000
WAGONER CO. RWD #6 1,500
WAGONER CO. RWD #1 397

Frequently asked questions about Wagoner tap water

Is Wagoner tap water safe to drink?

EPA testing detected 21 contaminants in the water serving Wagoner. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Wagoner?

5 public water suppliers report drinking-water monitoring for Wagoner, Oklahoma to the EPA. Each is listed above with its population served.

What contaminants are in Wagoner's water?

The contaminants EPA monitoring detected in Wagoner include Copper, Nitrate-Nitrite, TTHM, Fluoride, Chloroform. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.