← Ohio

Tap water quality report

Girard, OH

EPA monitoring detected 17 contaminants across the 1 water supplier serving Girard. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

1
water supplier
14,122
people served
17
contaminants found

What was found in Girard's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Copper
98.1 µg/L 7.5%
of the EPA limit 1300 µg/L
Main supplier: GIRARD CITY · 14,122 people · 2019
1/1 SYR4
TTHM
90.186 µg/L 113%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
Main supplier: GIRARD CITY · 14,122 people · 2019
1/1 SYR4
Chloroform
75.45 µg/L
No EPA limit set
Main supplier: GIRARD CITY · 14,122 people · 2019
1/1 SYR4
Total Haloacetic Acids (HAA5)
45.28 µg/L 75%
of the EPA limit 60 µg/L
Main supplier: GIRARD CITY · 14,122 people · 2019
1/1 SYR4
Dichloroacetic Acid
37.042 µg/L
No EPA limit set
Main supplier: GIRARD CITY · 14,122 people · 2019
1/1 SYR4
Bromodichloromethane
14.9015 µg/L
No EPA limit set
Main supplier: GIRARD CITY · 14,122 people · 2019
1/1 SYR4
Lead
11.9065 µg/L 79%
of the EPA limit 15 µg/L
Main supplier: GIRARD CITY · 14,122 people · 2019
1/1 SYR4
Trichloroacetic Acid
9.46155 µg/L
No EPA limit set
Main supplier: GIRARD CITY · 14,122 people · 2019
1/1 SYR4
Monochloroacetic Acid
5.5293 µg/L
No EPA limit set
Main supplier: GIRARD CITY · 14,122 people · 2019
1/1 SYR4
Dibromochloromethane
4.565 µg/L
No EPA limit set
Main supplier: GIRARD CITY · 14,122 people · 2019
1/1 SYR4
Monobromoacetic Acid
1.6815 µg/L
No EPA limit set
Main supplier: GIRARD CITY · 14,122 people · 2019
1/1 SYR4
PFOS
0.0201 µg/L
No EPA limit set
Main supplier: GIRARD CITY · 14,122 people · 2024
1/1 UCMR-5
PFHXS
0.0103 µg/L
No EPA limit set
Main supplier: GIRARD CITY · 14,122 people · 2024
1/1 UCMR-5
Pfba
0.0075 µg/L
No EPA limit set
Main supplier: GIRARD CITY · 14,122 people · 2024
1/1 UCMR-5
PFBS
0.0034 µg/L
No EPA limit set
Main supplier: GIRARD CITY · 14,122 people · 2024
1/1 UCMR-5
Pfhxa
0.0030 µg/L
No EPA limit set
Main supplier: GIRARD CITY · 14,122 people · 2024
1/1 UCMR-5
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
Main supplier: GIRARD CITY · 14,122 people · 2025
1/1 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Girard

SupplierPopulation served
GIRARD CITY 14,122

Frequently asked questions about Girard tap water

Is Girard tap water safe to drink?

EPA testing detected 17 contaminants in the water serving Girard. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Girard?

1 public water supplier report drinking-water monitoring for Girard, Ohio to the EPA. Each is listed above with its population served.

What contaminants are in Girard's water?

The contaminants EPA monitoring detected in Girard include Copper, TTHM, Chloroform, Total Haloacetic Acids (HAA5), Dichloroacetic Acid. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.