← New York

Tap water quality report

Salamanca, NY

EPA monitoring detected 31 contaminants across the 6 water suppliers serving Salamanca. A detection doesn't automatically mean the water is unsafe — see the highest level found for each below, with its EPA source and period.

6
water suppliers
11,502
people served
31
contaminants found

What was found in Salamanca's water

The highest level seen across the city's suppliers, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
2560 µg/L 26%
of the EPA limit 10000 µg/L
5/6 SYR4
Xylenes, Total
1000 µg/L 10%
of the EPA limit 10000 µg/L
2/6 SYR4
Barium
230 µg/L 12%
of the EPA limit 2000 µg/L
5/6 SYR4
Fluoride
210 µg/L 5.3%
of the EPA limit 4000 µg/L
3/6 SYR4
Total Haloacetic Acids (HAA5)
95.6 µg/L 159%
of the EPA limit, in the worst sample — 60 µg/L
3/6 SYR4
TTHM
77.5 µg/L 97%
of the EPA limit 80 µg/L
6/6 SYR4
Chromium
7 µg/L 7%
of the EPA limit 100 µg/L
3/6 SYR4
Dibromochloromethane
5.2 µg/L
No EPA limit set
1/6 SYR4
Cyanide
5 µg/L 2.5%
of the EPA limit 200 µg/L
3/6 SYR4
Bromodichloromethane
4.5 µg/L
No EPA limit set
1/6 SYR4
Bromoform
4.3 µg/L
No EPA limit set
1/6 SYR4
Dichloroacetic Acid
3.6 µg/L
No EPA limit set
1/6 SYR4
Chloroform
3.4 µg/L
No EPA limit set
1/6 SYR4
Gross Alpha, Excl. Radon And U
3.20585 pCi/L 21%
of the EPA limit 15 pCi/L
3/6 SYR4
Monochloroacetic Acid
2.9 µg/L
No EPA limit set
1/6 SYR4
Selenium
2 µg/L 4%
of the EPA limit 50 µg/L
2/6 SYR4
Di(2-ethylhexyl) Phthalate
1.99 µg/L 33%
of the EPA limit 6 µg/L
1/6 SYR4
Toluene
1.62 µg/L 0.2%
of the EPA limit 1000 µg/L
1/6 SYR4
Antimony, Total
1 µg/L 17%
of the EPA limit 6 µg/L
2/6 SYR4
Arsenic
1 µg/L 10%
of the EPA limit 10 µg/L
2/6 SYR4
Beryllium, Total
1 µg/L 25%
of the EPA limit 4 µg/L
2/6 SYR4
Cadmium
1 µg/L 20%
of the EPA limit 5 µg/L
2/6 SYR4
Combined Radium (-226 And -228)
0.5960 pCi/L 12%
of the EPA limit 5 pCi/L
3/6 SYR4
Trichloroethylene
0.5900 µg/L 12%
of the EPA limit 5 µg/L
1/6 SYR4
Combined Uranium
0.3777 µg/L 1.3%
of the EPA limit 30 µg/L
3/6 SYR4
Thallium, Total
0.3000 µg/L 15%
of the EPA limit 2 µg/L
1/6 SYR4
Mercury
0.2000 µg/L 10%
of the EPA limit 2 µg/L
3/6 SYR4
Asbestos
0.1800 MFL 2.6%
of the EPA limit 7 MFL
1/6 SYR4
Methoxychlor
0.1000 µg/L 0.3%
of the EPA limit 40 µg/L
1/6 SYR4
PFBS
0.0054 µg/L
No EPA limit set
1/6 UCMR-5
Lead
0.0026 mg/L 17%
of the EPA limit 0.0150 mg/L
6/6 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Salamanca

Frequently asked questions about Salamanca tap water

Is Salamanca tap water safe to drink?

EPA testing detected 31 contaminants in the water serving Salamanca. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Salamanca?

6 public water suppliers report drinking-water monitoring for Salamanca, New York to the EPA. Each is listed above with its population served.

What contaminants are in Salamanca's water?

The contaminants EPA monitoring detected in Salamanca include Nitrate, Xylenes, Total, Barium, Fluoride, Total Haloacetic Acids (HAA5). The full list, with the highest level found and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.