← North Carolina

Tap water quality report

Leland, NC

EPA monitoring detected 27 contaminants across the 3 water suppliers serving Leland. A detection doesn't automatically mean the water is unsafe — see the highest level found for each below, with its EPA source and period.

3
water suppliers
197,195
people served
27
contaminants found

What was found in Leland's water

The highest level seen across the city's suppliers, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Copper
15300 µg/L 1177%
of the EPA limit, in the worst sample — 1300 µg/L
3/3 SYR4
Nitrate
1770 µg/L 18%
of the EPA limit 10000 µg/L
1/3 SYR4
Chlorite
1250 µg/L 125%
of the EPA limit, in the worst sample — 1000 µg/L
1/3 SYR4
Fluoride
720 µg/L 18%
of the EPA limit 4000 µg/L
1/3 SYR4
TTHM
71 µg/L 89%
of the EPA limit 80 µg/L
2/3 SYR4
Total Haloacetic Acids (HAA5)
44 µg/L 73%
of the EPA limit 60 µg/L
2/3 SYR4
Chloroform
33.64 µg/L
No EPA limit set
2/3 SYR4
Dibromochloromethane
27.3 µg/L
No EPA limit set
2/3 SYR4
Dichloroacetic Acid
27 µg/L
No EPA limit set
2/3 SYR4
Bromodichloromethane
22.49 µg/L
No EPA limit set
2/3 SYR4
Bromoform
18.89 µg/L
No EPA limit set
2/3 SYR4
Monobromoacetic Acid
14 µg/L
No EPA limit set
2/3 SYR4
Dibromoacetic Acid
13 µg/L
No EPA limit set
2/3 SYR4
Lead
9 µg/L 60%
of the EPA limit 15 µg/L
2/3 SYR4
Trichloroacetic Acid
8 µg/L
No EPA limit set
2/3 SYR4
Monochloroacetic Acid
6 µg/L
No EPA limit set
2/3 SYR4
Combined Radium (-226 And -228)
1.2 pCi/L 24%
of the EPA limit 5 pCi/L
1/3 SYR4
PFOS
0.0124 µg/L
No EPA limit set
1/3 UCMR-5
Pfpea
0.0115 µg/L
No EPA limit set
1/3 UCMR-5
Pfhxa
0.0098 µg/L
No EPA limit set
1/3 UCMR-5
Pfba
0.0085 µg/L
No EPA limit set
1/3 UCMR-5
PFOA
0.0077 µg/L
No EPA limit set
1/3 UCMR-5
PFBS
0.0071 µg/L
No EPA limit set
1/3 UCMR-5
Hfpo-Da
0.0058 µg/L
No EPA limit set
1/3 UCMR-5
PFHXS
0.0052 µg/L
No EPA limit set
1/3 UCMR-5
Pfhpa
0.0041 µg/L
No EPA limit set
1/3 UCMR-5
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
3/3 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Leland

Frequently asked questions about Leland tap water

Is Leland tap water safe to drink?

EPA testing detected 27 contaminants in the water serving Leland. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Leland?

3 public water suppliers report drinking-water monitoring for Leland, North Carolina to the EPA. Each is listed above with its population served.

What contaminants are in Leland's water?

The contaminants EPA monitoring detected in Leland include Copper, Nitrate, Chlorite, Fluoride, TTHM. The full list, with the highest level found and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.