← North Carolina

Tap water quality report

Cherokee, NC

EPA monitoring detected 11 contaminants across the 4 water suppliers serving Cherokee. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

4
water suppliers
16,703
people served
11
contaminants found

What was found in Cherokee's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
365.5 µg/L 3.7%
of the EPA limit 10000 µg/L
Main supplier: CHEROKEE WATER SYSTEM · 16,203 people · 2019
Highest in the city: 3300 µg/L — CHEROKEE - ROUGH BRANCH WATER SYSTEM · 233 people · 2019
3/4 SYR4
Nitrate-Nitrite
353.5 µg/L 3.5%
of the EPA limit 10000 µg/L
Main supplier: CHEROKEE WATER SYSTEM · 16,203 people · 2019
Highest in the city: 2525 µg/L — CHEROKEE - ROUGH BRANCH WATER SYSTEM · 233 people · 2019
3/4 SYR4
Copper
21.62 µg/L 1.7%
of the EPA limit 1300 µg/L
Main supplier: CHEROKEE WATER SYSTEM · 16,203 people · 2018
Highest in the city: 972.6 µg/L — CHEROKEE - ROUGH BRANCH WATER SYSTEM · 233 people · 2017
4/4 SYR4
Nitrite
230 µg/L 23%
of the EPA limit 1000 µg/L
Highest in the city: CHEROKEE - ROUGH BRANCH WATER SYSTEM · 233 people · 2019
1/4 SYR4
Combined Radium (-226 And -228)
0.9601 pCi/L 19%
of the EPA limit 5 pCi/L
Main supplier: CHEROKEE WATER SYSTEM · 16,203 people · 2018
Highest in the city: 150.252 pCi/L — CHEROKEE - SNOWBIRD/CORNSILK COMMUNITY · 103 people · 2018
3/4 SYR4
Fluoride
86.9 µg/L 2.2%
of the EPA limit 4000 µg/L
Highest in the city: CHEROKEE - SNOWBIRD/CORNSILK COMMUNITY · 103 people · 2017
1/4 SYR4
Lead
29.5 µg/L 197%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
Main supplier: CHEROKEE WATER SYSTEM · 16,203 people · 2018
4/4 SYR4
Gross Alpha, Excl. Radon And U
0.9500 pCi/L 6.3%
of the EPA limit 15 pCi/L
Main supplier: CHEROKEE WATER SYSTEM · 16,203 people · 2018
Highest in the city: 23.2575 pCi/L — CHEROKEE - ROUGH BRANCH WATER SYSTEM · 233 people · 2018
3/4 SYR4
Barium
18.6 µg/L 0.9%
of the EPA limit 2000 µg/L
Highest in the city: CHEROKEE - ROUGH BRANCH WATER SYSTEM · 233 people · 2017
2/4 SYR4
Combined Uranium
1.14924 µg/L 3.8%
of the EPA limit 30 µg/L
Main supplier: CHEROKEE WATER SYSTEM · 16,203 people · 2017
Highest in the city: 1.16742 µg/L — CHEROKEE - SNOWBIRD/CORNSILK COMMUNITY · 103 people · 2015
3/4 SYR4
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
Main supplier: CHEROKEE WATER SYSTEM · 16,203 people · 2026
Highest in the city: 0.0070 mg/L — CHEROKEE- 3200 ACRE COMMUNITY WS · 164 people · 2025
4/4 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Cherokee

Frequently asked questions about Cherokee tap water

Is Cherokee tap water safe to drink?

EPA testing detected 11 contaminants in the water serving Cherokee. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Cherokee?

4 public water suppliers report drinking-water monitoring for Cherokee, North Carolina to the EPA. Each is listed above with its population served.

What contaminants are in Cherokee's water?

The contaminants EPA monitoring detected in Cherokee include Nitrate, Nitrate-Nitrite, Copper, Nitrite, Combined Radium (-226 And -228). The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.