← Missouri

Tap water quality report

Brookfield, MO

EPA monitoring detected 19 contaminants across the 2 water suppliers serving Brookfield. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

2
water suppliers
9,311
people served
19
contaminants found

What was found in Brookfield's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Fluoride
883 µg/L 22%
of the EPA limit 4000 µg/L
Highest in the city: BROOKFIELD PWS · 4,111 people · 2019
1/2 SYR4
Nitrate-Nitrite
420 µg/L 4.2%
of the EPA limit 10000 µg/L
Highest in the city: BROOKFIELD PWS · 4,111 people · 2019
1/2 SYR4
TTHM
82.59 µg/L 103%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
Main supplier: CHARITON LINN COUNTY PWSD 3 · 5,200 people · 2019
2/2 SYR4
Copper
38.03 µg/L 2.9%
of the EPA limit 1300 µg/L
Main supplier: CHARITON LINN COUNTY PWSD 3 · 5,200 people · 2017
Highest in the city: 77.48 µg/L — BROOKFIELD PWS · 4,111 people · 2019
2/2 SYR4
Barium
73.435 µg/L 3.7%
of the EPA limit 2000 µg/L
Highest in the city: BROOKFIELD PWS · 4,111 people · 2019
1/2 SYR4
Chloroform
66.5 µg/L
No EPA limit set
Main supplier: CHARITON LINN COUNTY PWSD 3 · 5,200 people · 2019
2/2 SYR4
Total Haloacetic Acids (HAA5)
44.85 µg/L 75%
of the EPA limit 60 µg/L
Main supplier: CHARITON LINN COUNTY PWSD 3 · 5,200 people · 2019
2/2 SYR4
Dichloroacetic Acid
32.760000000000005 µg/L
No EPA limit set
Main supplier: CHARITON LINN COUNTY PWSD 3 · 5,200 people · 2019
2/2 SYR4
Bromodichloromethane
15.24 µg/L
No EPA limit set
Main supplier: CHARITON LINN COUNTY PWSD 3 · 5,200 people · 2019
Highest in the city: 16 µg/L — BROOKFIELD PWS · 4,111 people · 2019
2/2 SYR4
Lead
12.623999999999995 µg/L 84%
of the EPA limit 15 µg/L
Main supplier: CHARITON LINN COUNTY PWSD 3 · 5,200 people · 2017
Highest in the city: 14.99999999999999 µg/L — BROOKFIELD PWS · 4,111 people · 2019
2/2 SYR4
Trichloroacetic Acid
13.600000000000005 µg/L
No EPA limit set
Main supplier: CHARITON LINN COUNTY PWSD 3 · 5,200 people · 2019
Highest in the city: 14.944999999999999 µg/L — BROOKFIELD PWS · 4,111 people · 2019
2/2 SYR4
Monochloroacetic Acid
10.9 µg/L
No EPA limit set
Main supplier: CHARITON LINN COUNTY PWSD 3 · 5,200 people · 2019
2/2 SYR4
Monobromoacetic Acid
8.945 µg/L
No EPA limit set
Main supplier: CHARITON LINN COUNTY PWSD 3 · 5,200 people · 2019
Highest in the city: 9.41 µg/L — BROOKFIELD PWS · 4,111 people · 2019
2/2 SYR4
Dibromochloromethane
5.19 µg/L
No EPA limit set
Main supplier: CHARITON LINN COUNTY PWSD 3 · 5,200 people · 2019
Highest in the city: 6.754 µg/L — BROOKFIELD PWS · 4,111 people · 2019
2/2 SYR4
Dibromoacetic Acid
1.9970000000000003 µg/L
No EPA limit set
Main supplier: CHARITON LINN COUNTY PWSD 3 · 5,200 people · 2019
Highest in the city: 2.2455 µg/L — BROOKFIELD PWS · 4,111 people · 2019
2/2 SYR4
Chromium
1.653 µg/L 1.7%
of the EPA limit 100 µg/L
Highest in the city: BROOKFIELD PWS · 4,111 people · 2019
1/2 SYR4
Bromoform
1.0279999999999998 µg/L
No EPA limit set
Main supplier: CHARITON LINN COUNTY PWSD 3 · 5,200 people · 2019
2/2 SYR4
Lead
0.0014 mg/L 9.6%
of the EPA limit 0.0150 mg/L
Main supplier: CHARITON LINN COUNTY PWSD 3 · 5,200 people · 2025
Highest in the city: 0.0094 mg/L — BROOKFIELD PWS · 4,111 people · 2024
2/2 LCR
Pfba
0.0072 µg/L
No EPA limit set
Main supplier: CHARITON LINN COUNTY PWSD 3 · 5,200 people · 2024
2/2 UCMR-5
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Brookfield

SupplierPopulation served
CHARITON LINN COUNTY PWSD 3 5,200
BROOKFIELD PWS 4,111

Frequently asked questions about Brookfield tap water

Is Brookfield tap water safe to drink?

EPA testing detected 19 contaminants in the water serving Brookfield. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Brookfield?

2 public water suppliers report drinking-water monitoring for Brookfield, Missouri to the EPA. Each is listed above with its population served.

What contaminants are in Brookfield's water?

The contaminants EPA monitoring detected in Brookfield include Fluoride, Nitrate-Nitrite, TTHM, Copper, Barium. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.