What was found in Grafton's water
The highest level seen across the city's suppliers, the EPA limit for each, and where the figure comes from.
| Contaminant | Level vs EPA limit | Suppliers | Source |
|---|---|---|---|
| Nitrate | 3700 µg/L 37% of the EPA limit 10000 µg/L | 4/4 | SYR4 |
| Fluoride | 1500 µg/L 38% of the EPA limit 4000 µg/L | 2/4 | SYR4 |
| Copper | 429 µg/L 33% of the EPA limit 1300 µg/L | 1/4 | SYR4 |
| Barium | 270 µg/L 14% of the EPA limit 2000 µg/L | 2/4 | SYR4 |
| TTHM | 93 µg/L 116% of the EPA limit, in the worst sample — 80 µg/L | 2/4 | SYR4 |
| Total Haloacetic Acids (HAA5) | 42 µg/L 70% of the EPA limit 60 µg/L | 2/4 | SYR4 |
| Chloroform | 34.5 µg/L No EPA limit set | 2/4 | SYR4 |
| 1,1,1-Trichloroethane | 30 µg/L 15% of the EPA limit 200 µg/L | 1/4 | SYR4 |
| Bromodichloromethane | 27.4 µg/L No EPA limit set | 2/4 | SYR4 |
| Dibromochloromethane | 22 µg/L No EPA limit set | 2/4 | SYR4 |
| cis-1,2-Dichloroethylene | 21 µg/L 30% of the EPA limit 70 µg/L | 1/4 | SYR4 |
| Dichloroacetic Acid | 14.1 µg/L No EPA limit set | 1/4 | SYR4 |
| Trichloroacetic Acid | 14 µg/L No EPA limit set | 1/4 | SYR4 |
| Trichloroethylene | 12 µg/L 240% of the EPA limit, in the worst sample — 5 µg/L | 1/4 | SYR4 |
| Arsenic | 7.8 µg/L 78% of the EPA limit 10 µg/L | 1/4 | SYR4 |
| Monobromoacetic Acid | 6.2 µg/L No EPA limit set | 1/4 | SYR4 |
| Monochloroacetic Acid | 6.1 µg/L No EPA limit set | 1/4 | SYR4 |
| Bromoform | 5.2 µg/L No EPA limit set | 2/4 | SYR4 |
| Dibromoacetic Acid | 5.1 µg/L No EPA limit set | 1/4 | SYR4 |
| Lead | 2.9 µg/L 19% of the EPA limit 15 µg/L | 1/4 | SYR4 |
| 1,1-Dichloroethylene | 2.3 µg/L 33% of the EPA limit 7 µg/L | 1/4 | SYR4 |
| Tetrachloroethylene | 1.1 µg/L 22% of the EPA limit 5 µg/L | 1/4 | SYR4 |
| Lead | 0.0144 mg/L 96% of the EPA limit 0.0150 mg/L | 4/4 | LCR |
| PFOA | 0.0069 µg/L No EPA limit set | 1/4 | UCMR-5 |
| PFOS | 0.0069 µg/L No EPA limit set | 1/4 | UCMR-5 |
| Pfhxa | 0.0036 µg/L No EPA limit set | 1/4 | UCMR-5 |
| Pfpea | 0.0035 µg/L No EPA limit set | 1/4 | UCMR-5 |
| PFBS | 0.0031 µg/L No EPA limit set | 1/4 | UCMR-5 |
Water suppliers serving Grafton
| Supplier | Population served |
|---|---|
| GRAFTON WATER DISTRICT | 10,925 |
| SOUTH GRAFTON WATER DISTRICT | 3,262 |
| LAUREL HILL CONDOMINIUMS | 64 |
| COUNTRYSIDE CONDOMINIUM | 30 |
Frequently asked questions about Grafton tap water
Is Grafton tap water safe to drink?
EPA testing detected 28 contaminants in the water serving Grafton. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.
How many water suppliers serve Grafton?
4 public water suppliers report drinking-water monitoring for Grafton, Massachusetts to the EPA. Each is listed above with its population served.
What contaminants are in Grafton's water?
The contaminants EPA monitoring detected in Grafton include Nitrate, Fluoride, Copper, Barium, TTHM. The full list, with the highest level found and the data source, is in the table above.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.