← California

Tap water quality report

Pasadena, CA

EPA monitoring detected 32 contaminants across the 6 water suppliers serving Pasadena. A detection doesn't automatically mean the water is unsafe — see the highest level found for each below, with its EPA source and period.

6
water suppliers
192,298
people served
32
contaminants found

What was found in Pasadena's water

The highest level seen across the city's suppliers, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
37300 µg/L 373%
of the EPA limit, in the worst sample — 10000 µg/L
4/6 SYR4
Fluoride
3300 µg/L 83%
of the EPA limit 4000 µg/L
5/6 SYR4
Nitrate-Nitrite
1600 µg/L 16%
of the EPA limit 10000 µg/L
1/6 SYR4
Barium
440 µg/L 22%
of the EPA limit 2000 µg/L
2/6 SYR4
Copper
230 µg/L 18%
of the EPA limit 1300 µg/L
2/6 SYR4
Lead
220 µg/L 1467%
of the EPA limit, in the worst sample — 15 µg/L
2/6 SYR4
Arsenic
140 µg/L 1400%
of the EPA limit, in the worst sample — 10 µg/L
5/6 SYR4
Combined Uranium
134.547 µg/L 448%
of the EPA limit, in the worst sample — 30 µg/L
4/6 SYR4
TTHM
118 µg/L 148%
of the EPA limit, in the worst sample — 80 µg/L
6/6 SYR4
Toluene
72 µg/L 7.2%
of the EPA limit 1000 µg/L
2/6 SYR4
Lithium
64.2 µg/L
No EPA limit set
1/6 UCMR-5
Chloroform
44.5 µg/L
No EPA limit set
6/6 SYR4
Bromodichloromethane
37.9 µg/L
No EPA limit set
6/6 SYR4
Total Haloacetic Acids (HAA5)
34 µg/L 57%
of the EPA limit 60 µg/L
6/6 SYR4
Dibromochloromethane
31 µg/L
No EPA limit set
5/6 SYR4
Trichloroethylene
31 µg/L 620%
of the EPA limit, in the worst sample — 5 µg/L
2/6 SYR4
cis-1,2-Dichloroethylene
20.7 µg/L 30%
of the EPA limit 70 µg/L
1/6 SYR4
Bromoform
18.2 µg/L
No EPA limit set
4/6 SYR4
Dichloroacetic Acid
17 µg/L
No EPA limit set
6/6 SYR4
Tetrachloroethylene
13.8 µg/L 276%
of the EPA limit, in the worst sample — 5 µg/L
2/6 SYR4
Chromium
12 µg/L 12%
of the EPA limit 100 µg/L
3/6 SYR4
Trichloroacetic Acid
11 µg/L
No EPA limit set
5/6 SYR4
Dibromoacetic Acid
9 µg/L
No EPA limit set
4/6 SYR4
trans-1,2-Dichloroethylene
4.2 µg/L 4.2%
of the EPA limit 100 µg/L
1/6 SYR4
Carbon Tetrachloride
4.01 µg/L 80%
of the EPA limit 5 µg/L
2/6 SYR4
Di(2-ethylhexyl) Phthalate
3.7 µg/L 62%
of the EPA limit 6 µg/L
1/6 SYR4
Monochloroacetic Acid
3.2 µg/L
No EPA limit set
1/6 SYR4
Monobromoacetic Acid
1.3 µg/L
No EPA limit set
2/6 SYR4
1,1-Dichloroethylene
0.9100 µg/L 13%
of the EPA limit 7 µg/L
1/6 SYR4
Dichloromethane
0.5400 µg/L 11%
of the EPA limit 5 µg/L
1/6 SYR4
Xylenes, Total
0.0800 µg/L 0%
of the EPA limit 10000 µg/L
1/6 SYR4
Lead
0.0194 mg/L 129%
above the EPA limit of 0.0150 mg/L
6/6 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Pasadena

Frequently asked questions about Pasadena tap water

Is Pasadena tap water safe to drink?

EPA testing detected 32 contaminants in the water serving Pasadena. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Pasadena?

6 public water suppliers report drinking-water monitoring for Pasadena, California to the EPA. Each is listed above with its population served.

What contaminants are in Pasadena's water?

The contaminants EPA monitoring detected in Pasadena include Nitrate, Fluoride, Nitrate-Nitrite, Barium, Copper. The full list, with the highest level found and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.