← Arkansas

Tap water quality report

Dequeen, AR

EPA monitoring detected 19 contaminants across the 2 water suppliers serving Dequeen. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

2
water suppliers
11,470
people served
19
contaminants found

What was found in Dequeen's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Copper
1035.999999999998 µg/L 80%
of the EPA limit 1300 µg/L
Main supplier: DEQUEEN WATER WORK · 6,105 people · 2017
2/2 SYR4
Fluoride
883.5000000000001 µg/L 22%
of the EPA limit 4000 µg/L
Main supplier: DEQUEEN WATER WORK · 6,105 people · 2019
1/2 SYR4
Nitrate-Nitrite
300 µg/L 3%
of the EPA limit 10000 µg/L
Main supplier: DEQUEEN WATER WORK · 6,105 people · 2019
Highest in the city: 583.4999999999998 µg/L — SEVIER CO WATER ASSOCIATION · 5,365 people · 2019
2/2 SYR4
Nitrate
360 µg/L 3.6%
of the EPA limit 10000 µg/L
Highest in the city: SEVIER CO WATER ASSOCIATION · 5,365 people · 2017
1/2 SYR4
TTHM
48.04 µg/L 60%
of the EPA limit 80 µg/L
Main supplier: DEQUEEN WATER WORK · 6,105 people · 2019
Highest in the city: 104 µg/L — SEVIER CO WATER ASSOCIATION · 5,365 people · 2019
2/2 SYR4
Chloroform
43.56 µg/L
No EPA limit set
Main supplier: DEQUEEN WATER WORK · 6,105 people · 2019
Highest in the city: 95.51999999999998 µg/L — SEVIER CO WATER ASSOCIATION · 5,365 people · 2019
2/2 SYR4
Total Haloacetic Acids (HAA5)
19.12 µg/L 32%
of the EPA limit 60 µg/L
Main supplier: DEQUEEN WATER WORK · 6,105 people · 2019
Highest in the city: 43.975 µg/L — SEVIER CO WATER ASSOCIATION · 5,365 people · 2019
2/2 SYR4
Dichloroacetic Acid
7.419999999999997 µg/L
No EPA limit set
Main supplier: DEQUEEN WATER WORK · 6,105 people · 2019
Highest in the city: 26.875 µg/L — SEVIER CO WATER ASSOCIATION · 5,365 people · 2019
2/2 SYR4
Lead
23.609999999999996 µg/L 157%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
Main supplier: DEQUEEN WATER WORK · 6,105 people · 2019
2/2 SYR4
Trichloroacetic Acid
12.82 µg/L
No EPA limit set
Main supplier: DEQUEEN WATER WORK · 6,105 people · 2019
Highest in the city: 16.36 µg/L — SEVIER CO WATER ASSOCIATION · 5,365 people · 2019
2/2 SYR4
Bromodichloromethane
6.9399999999999995 µg/L
No EPA limit set
Main supplier: DEQUEEN WATER WORK · 6,105 people · 2019
Highest in the city: 8.189999999999998 µg/L — SEVIER CO WATER ASSOCIATION · 5,365 people · 2019
2/2 SYR4
Monochloroacetic Acid
3.425 µg/L
No EPA limit set
Highest in the city: SEVIER CO WATER ASSOCIATION · 5,365 people · 2019
1/2 SYR4
Gross Beta Particle Activity
3.1 pCi/L
No EPA limit set
Main supplier: DEQUEEN WATER WORK · 6,105 people · 2019
2/2 SYR4
Dibromochloromethane
1.1809999999999998 µg/L
No EPA limit set
Main supplier: DEQUEEN WATER WORK · 6,105 people · 2019
Highest in the city: 1.2 µg/L — SEVIER CO WATER ASSOCIATION · 5,365 people · 2019
2/2 SYR4
Dibromoacetic Acid
1.1 µg/L
No EPA limit set
Highest in the city: SEVIER CO WATER ASSOCIATION · 5,365 people · 2019
1/2 SYR4
Monobromoacetic Acid
1.1 µg/L
No EPA limit set
Highest in the city: SEVIER CO WATER ASSOCIATION · 5,365 people · 2019
1/2 SYR4
Benzo(A)Pyrene
0.1065 µg/L 53%
of the EPA limit 0.2000 µg/L
Main supplier: DEQUEEN WATER WORK · 6,105 people · 2019
1/2 SYR4
Hexachlorocyclopentadiene
0.0200 µg/L 0%
of the EPA limit 50 µg/L
Highest in the city: SEVIER CO WATER ASSOCIATION · 5,365 people · 2018
1/2 SYR4
Lead
0.0010 mg/L 6.7%
of the EPA limit 0.0150 mg/L
Main supplier: DEQUEEN WATER WORK · 6,105 people · 2025
Highest in the city: 0.0030 mg/L — SEVIER CO WATER ASSOCIATION · 5,365 people · 2025
2/2 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Dequeen

SupplierPopulation served
DEQUEEN WATER WORK 6,105
SEVIER CO WATER ASSOCIATION 5,365

Frequently asked questions about Dequeen tap water

Is Dequeen tap water safe to drink?

EPA testing detected 19 contaminants in the water serving Dequeen. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Dequeen?

2 public water suppliers report drinking-water monitoring for Dequeen, Arkansas to the EPA. Each is listed above with its population served.

What contaminants are in Dequeen's water?

The contaminants EPA monitoring detected in Dequeen include Copper, Fluoride, Nitrate-Nitrite, Nitrate, TTHM. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.